| Recommended Cleaning Guidelines: |
| Clean reflowed residues with hot
deionizd water at a minimum temperature of 40°C.
If pressurized cleaners are used a minimum pressure
of 40 psi should be maintained. If cosolvents or saponmifiers
are used with ultrasonic cleaners then a minimum of
two deionized rinse baths should be used to insure complete
removal of the residues an cleaning solvents. For optimal
results clean parts as soon after reflow as possible.
Residues can also be cleaned in cold water washing systems
at temperatures as low as 25°C. To clean wet paste
prior to reflow use isopropyl alcohol or similar solvents. |
| Packaging: |
Available in 5, 10 and
30cc syringes.
250, 500 and 1000 gram jars.
6 ounce, 12 ounce and ProFlow |
| Safety: |
| When using do not eat,
drink, or smoke. Avoid contact with skin and eyes. Wear
suitable gloves and eye protection. Contains lead! |
| Warranty: |
| Material guaranteed
to meet specifications for 6 months from date of shipment |
| Storage: |
| Paste in jars can be
stored at room temperature (20-25°C). Syringes and
cartridges should be refrigerated at 5-12°C. If
paste is to be stored more than 2 months before use,
refrigeration 5-12°C is recommended. Avoid direct
sunlight and temperatures exceeding 35°C. Allow
paste to come to room temperature for a minimum of 2
hours prior to opening. Store more syringes and cartridges
with tips down. |
|
|
|